CVE-2019-6575
Beschrijving NL
Er is een kwetsbaarheid vastgesteld in SIMATIC CP 443-1 OPC UA (Alle versies), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS-varianten) (Alle versies < V2.7), SIMATIC HMI Comfort Outdoor Panelen 7" & 15" (incl. SIPLUS-varianten) (Alle versies < V15.1 Upd 4), SIMATIC HMI Comfort Panelen 4" - 22" (incl. SIPLUS-varianten) (Alle versies < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 en KTP900F (Alle versies < V15.1 Upd 4), SIMATIC IPC DiagMonitor (Alle versies < V5.1.3), SIMATIC NET PC Software V13 (Alle versies), SIMATIC NET PC Software V14 (Alle versies < V14 SP1 Update 14), SIMATIC NET PC Software V15 (Alle versies), SIMATIC RF188C (Alle versies < V1.1.0), SIMATIC RF600R-familie (Alle versies = V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (Alle versies tussen V2.5 (inclusief) en V2.7 (exclusief)), SIMATIC WinCC OA (Alle versies < V3.15 P018), SIMATIC WinCC Runtime Advanced (Alle versies < V15.1 Upd 4), SINEC NMS (Alle versies < V1.0 SP1), SINEMA Server (Alle versies < V14 SP2), SINUMERIK OPC UA Server (Alle versies < V2.1), TeleControl Server Basic (Alle versies < V3.1.1). Speciaal vervaardigde netwerkpakketten die naar getroffen apparaten op poort 4840/tcp worden verzonden, kunnen een niet-geverifieerde externe aanvaller in staat stellen om een denial of service-toestand van de OPC-communicatie te veroorzaken of het apparaat te laten crashen. Het beveiligingslek kan worden misbruikt door een aanvaller met netwerktoegang tot de getroffen systemen. Succesvolle exploitatie vereist geen systeemprivileges en geen gebruikersinteractie. Een aanvaller kan de kwetsbaarheid gebruiken om de beschikbaarheid van de OPC-communicatie in gevaar te brengen.
Origineel (Engels) tonen
A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R family (All versions = V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions < V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication.